Osculati - Master catalogue 2024

203 Electrical materials 14 E14.921.37 E14.921.35/36 E14.921.35/36 LITTELFUSE® bistable automatic smart latching relay IP67 It connects the battery banks (starting + services) when alternator/battery charger are working and it disconnects the banks when the charging system stops. It stands power peaks (i.e. powerful inverters). In case of emergency battery banks can be connected with a simple switch control. It complies with ISO 8846/SAEJ1171. Deutsch 6-pole DTM male connector. Battery switches Code V Max capacity A Control current Relay contact position for 10 sec continuo us closes (30 sec) with voltage closes (90 sec) with voltage opens (10 sec) with voltage opens (30 sec) with voltage opens circuit 14.921.35 12 1500 300 40 mA*/6 A** 13.5 V 13.1 V 12.3 V 2.7 V 16.5 V*** 14.921.36 24 1500 300 40 mA*/3 A** 27.0 V 26.0 V 24.0 V 25.5 V 32.4 V*** 14.921.37 Deutsch 6-pole DTM female connector (DTM 06-65). * At rest ** In activation phase, 50 m/sec. *** System protection E14.691.04 E14.691.06 E14.691.04/06 E14.691.06 E14.691.90 Settable electric touch panel with CAN-BUS MODULAR BACKLIGHT AUTOMATIC FUSE Touch modular panel made of glass and with backlit symbols. It comes with 48 stickers indicating the different functions and to be applied under the glass so that the surface is smooth and gives a printlike effect. Every switch can be set in 3 different modes: - Traditional ON-OFF: press a key to activate/deactivate the relating function. Ex. COCKPIT LIGHTS ----------------------------------------------- - Temporary (ON)-OFF: this function is active only when the key is pressed. Ex. 1: switch – HORN Ex. 2: switches – WINDLASS UP/DOWN ----------------------------------------------- - ALTERNATE ON-OFF: two keys can be set to activate a function and deactivate another and vice versa. Ex.: BILGE PUMP IN MANUAL/AUTOMATIC MODE. ----------------------------------------------- The keys are backlit in yellow when in standard mode, in blue when the function is active and in red in case of short circuit. The panels are designed to be modular: if placed side by side in vertical and/or horizontal position, they look like a single built-in panel with 4, 6, 8 (4 + 4), 12 (6 + 6) switches and so on. The connection between the CAN-BUS and the panel is wired by means of a quick fitting. 1.5-m cable and another 1.5-m extension cord can be added. The MOSFET module is a protection against overloads and voltage inversions. The CAN-BUS is fitted with 4 or 6 thermal fuses that activate in case of short circuit (function key lit in red). The fuse can be reset automatically once the short circuit has been solved and the key is then lit in yellow. CE-certified panels, IP67 protection degree. Modular panels Code No. of switches V Circuit breaker power panel mm Installation bore Ø mm control box mm 1.5-m extension cable 14.691.04 4 12/24 1x5A; 2x10A; 1x15A 62x62x10 16 100.5x152 14.691.90 14.691.05 4 12/24 2x10A; 2x20A 62x62x10 16 100,5x152 14.691.90 14.691.06 6 12/24 2x5A; 2x10A; 2x15A 93x62x10 16 100.5x152 14.691.90

RkJQdWJsaXNoZXIy MjM2MTk=