87 Centaur Charger 12/20 12/30 24/16 12/40 12/50 12/60 24/30 12/80 24/40 12/100 24/60 Input voltage (V AC) 90 – 265 Input voltage (V DC) 90 – 400 Input frequency (Hz) 45 – 65 Power factor 1 Charge voltage ‘absorption’ (V DC) 14,3 / 28,5 (1) Charge voltage ‘float’ (V DC) 13,5 / 27,0 (1) Output banks 3 Charge current (A) (2) 20 30 / 16 40 50 60 / 30 80 / 40 100 / 60 Total output ammeter Yes Charge characteristic IUoU (Three stage charging) Recommended battery capacity (Ah) 80 - 200 120 - 300 45 - 150 160 - 400 200 - 500 240 - 600 120 - 300 320 - 800 160 - 400 400 - 1000 240 - 600 Temperature sensor Internal, - 2mV / °C (- 1mV / °F) per cell Forced cooling Yes, temperature and current controlled fan Protection Output short circuit, over temperature Operating temp. range - 20 to 60°C (0 - 140°F) Ignition protected Yes Humidity (non condensing) max 95% ENCLOSURE Material & Colour aluminium (blue RAL 5012) Battery-connection M6 studs M6 studs M8 studs M8 studs M8 studs M8 studs M8 studs AC-connection screw-clamp 4 mm² (AWG 6) Protection category IP 20 Weight kg (lbs) 3,8 (8.4) 3,8 (8.4) 5 (11) 5 (11) 5 (11) 12 (26) 12 (26) Dimensions hxwxd in mm (hxwxd in inches) 351x214x110 (13.8x8.4x4.3) 351x214x110 (13.8x8.4x4.3) 437x239x110 (17.2x9.4x4.3) 437x239x110 (17.2x9.4x4.3) 437x239x110 (17.2x9.4x4.3) 514x252x123 (20.2x9.9x4.8) 514x252x123 (20.2x9.9x4.8) STANDARDS Safety EN 60335-1, EN 60335-2-29, UL 1236 Emission Immunity EN 55014-1, EN 61000-3-2 Automotive Directive EN 55014-2, EN 61000-3-3 1) Standard setting. Optimum charge/float voltages for Flooded Lead-acid, Gel-Cell or AGM batteries selectable by DIP switch. 2) Up to 40°C (100°F) ambient. Output will reduce to approximately 80% of nominal at 50°C (120°F) and 60% of nominal at 60°C (140°F). BMV-700 Battery Monitor The BMV-700 Battery Monitor features an advanced microprocessor control system combined with high resolution measuring systems for battery voltage and charge/discharge current. Besides this, the software includes complex calculation algorithms, like Peukert’s formula, to exactly determine the state of charge of the battery. The BMV-700 selectively displays battery voltage, current, consumed Ah or time to go. Battery Alarm An excessively high or low battery voltage is indicated by an audible and visual alarm. Installation made easy 1. Fasten the separate mounting plate (A) to the wall where you want to place the battery charger, and simply hook up the Centaur. 2. Secure the bottom of the backside (B) to the wall.
RkJQdWJsaXNoZXIy MjM2MTk=