85 Skylla-TG 24/30 GMDSS 24/50 GMDSS Input voltage (V AC) 120 / 230 Input voltage range (V AC) 90 - 265 Frequency (Hz) 45-65 Power factor 1 Charge voltage 'absorption' (V DC) 28,5 Charge voltage 'float' (V DC) 26,5 Charge current (A) 30 (limited to 22 A at 110 V AC) 50 Charge characteristic IUoUo (three step) Temperature sensor √ Can be used as power supply √ Forced cooling √ Protection (1) a, b, c, d Operating temp. range -40 to +50°C (-40 - 122°F) Humidity (non-condensing) max 95% ENCLOSURE Material & Colour aluminium (blue RAL 5012) Battery-connection Two 1,5 m cables GMDSS connection One 1,5 m cable (+ to be taken directly from the battery) 230 V AC-connection Three wire 2,5 mm² (AWG 6) cable Length: 2 m Protection category IP 21 Weight kg (lbs) 6 (13) Dimensions hxwxd in mm (hxwxd in inches) 485x250x147 (19.1x9.9x5.8) ACCESORIES VE.Net GMDSS panel To be ordered separately UTP-cable To be ordered separately STANDARDS Safety EN 60335-1, EN 60335-2-29 Emission Immunity EN 55014-1, EN 61000-3-2 Immunity EN 55014-2, EN 61000-3-3 Maritime Nav. & Radiocomm. IEC 60945 1) Protection key: a) Output short circuit b) Battery reverse polarity detection c) Battery voltage too high d) Temperature too high 2) Up to 40°C (100°F) ambient Remote panel GMDSS The remote panel allows easy access to all important data. Alarm settings are pre-set but can also be reprogrammed.