81 Victron Energy B.V. | De Paal 35 | 1351 JG Almere | The Netherlands General phone: +31 (0)36 535 97 00 | E-mail: sales@victronenergy.com www.victronenergy.com Skylla TG 24/30 TG 24/50 TG 24/50 TG 3 phase 24/80 TG 24/100 TG 24/100 TG 3 phase 48/25 TG 48/50 TG Input voltage (V AC) 120/230 230 3 x 400 230 230 3 x 400 230 230 Input voltage range (V AC) 95-264 185-264 320-450 185-264 185-264 320-450 185-264 185-264 Input voltage range (V DC) 120-400 180-400 n. a. 180-400 180-400 n. a. 180-400 180-400 Frequency (Hz) 45-65 Power factor 1 Charge voltage 'absorption' (V DC) 28.5 28.5 28.5 28.5 28.5 57 57 Charge voltage 'float' (V DC) 26.5 26.5 26.5 26.5 26.5 53 53 Charge current house batt. (A) (2) 30 50 50 80 100 100 25 50 Charge current house batt. at 110 VAC (A) (3) 30 30 n. a. 60 60 n. a. 15 30 Charge current starter batt. (A) 4 4 4 4 4 n. a. n. a. Charge characteristic IUoUo (three step) Battery capacity (Ah) 150-500 250-500 400-800 500-1000 500-1000 125-250 250-500 Temperature sensor √ Can be used as power supply √ Remote alarm Potential free contacts 60V / 1A (1x NO and 1x NC) Forced cooling √ Protection (1) a,b,c,d Operating temp. range -40 to +50°C (-40 - 122°F) Humidity (non-condensing) max 95% ENCLOSURE Material & Colour aluminium (blue RAL 5012) Battery-connection M8 studs 230 V AC-connection screw-clamp 2,5 mm² (AWG 6) Protection category IP 21 Weight kg (lbs) 5,5 (12.1) 13 (28) 10 (22) 10 (22) 23 (48) 5,5 (12.1) 10 (22) Dimensions hxwxd in mm (hxwxd in inches) 365 x 250 x 147 (14.4 x 9.9 x 5.8) 365 x 250 x 257 (14.4 x 9.9 x 10.1) 515 x 260 x 265 (20 x 10.2 x 10.4) 365 x 250 x 147 (14.4 x 9.9 x 5.8) 365 x 250 x 257 (14.4 x 9.9 x 10.1) STANDARDS Safety EN 60335-1, EN 60335-2-29 Emission EN 55014-1, EN 61000-3-2 Immunity EN 55014-2, EN 61000-3-3 1) Protection a. Output short circuit b. Battery reverse polarity detection 2) Up to 40°C (100°F) ambient and at the specified input voltage range 3) Up to 40°C (100°F) ambient and at 110 VAC input voltage c. Battery voltage too high d. Temperature too high BMV-700Battery Monitor The BMV-700 Battery Monitor features an advanced microprocessor control system combined with high resolution measuring systems for battery voltage and charge/discharge current. Besides this, the software includes complex calculation algorithms, like Peukert’s formula, to exactly determine the state of charge of the battery. The BMV-700 selectively displays battery voltage, current, consumed Ah or time to go. Skylla Control The Skylla Control allows you to alter the charge current and see the system status. Altering the charge current is useful if the shore power fuse is limited: the AC current drawn by the battery charger can be controlled by limiting the maximum output current, thereby preventing the shore power fuse from blowing. Charger Switch A remote on-off switch Battery Alarm An excessively high or low battery voltage is indicated by an audible and visual alarm.
RkJQdWJsaXNoZXIy MjM2MTk=