65 Quattro 12/3000/120-50/50 24/3000/70-50/50 12/5000/220-100/100 24/5000/120-100/100 48/5000/70-100/100 24/8000/200-100/100 48/8000/110-100/100 48/10000/140-100/100 48/15000/200-100/100 Nominal Battery Voltage 12/3000: 12 Vbattery 24/3000: 24 V battery 12/5000: 12 V battery 24/5000: 24 V battery 48/5000: 48 VBatttery 24/8000: 24 V battery 48/8000: 48 V battery 48 V battery PowerControl / PowerAssist Yes Integrated Transfer switch Yes AC inputs (2x) Input voltage range: 187-250 VAC Input frequency: 50/60 Hz Cos Φ >0.8 Maximum feed through current (A) 2x 50 2x100 2x100 2x100 2x100 ICw 6 kA 30 mS 10 kA 30 ms INVERTER Input voltage range (VDC) 9,5 – 17 V 19–33V 38 –66V Output (1) Output voltage: 230 VAC ± 2 % Frequency: 50 Hz ± 0,1 % Cont. output power at 25 °C (VA) (3) 3000 5000 8000 10000 15000 Cont. output power at 25 °C (W) 2400 4000 6400 8000 12000 Cont. output power at 40 °C (W) 2200 3700 5500 6500 10000 Cont. output power at 65 °C (W) 1700 3000 3600 4500 7000 Peak power (W) 6000 10000 16000 20000 25000 Input current (A DC) 250 / 125 458/238/118 381/188 235 350 Maximum continuous Output current (A~) 11 19 30 37 53/50 Power factor range ±0.8 ±0.8 ±0.8 ±0.8 ±0.8 Maximum output fault current 32 A peak 1 sec. 53 A 1 sec. 100 A 1 sec 100 A 1 sec 150 A 1 sec Maximum efficiency (%) 93 / 94 94 / 94 / 95 94 / 96 96 96 Zero load power (W) 20 / 20 30 / 30 / 35 60 / 60 60 110 Zero load power in AES mode (W) 15 / 15 20 / 25 / 30 40 / 40 40 75 Zero load power in Search mode (W) 8 / 10 10 / 10 / 15 15 / 15 15 20 CHARGER Charge voltage 'absorption' (VDC) 14,4 / 28,8 14,4 / 28,8 / 57,6 28,8 / 57,6 57,6 57,6 Charge voltage 'float' (VDC) 13,8 / 27,6 13,8 / 27,6 / 55,2 27,6 / 55,2 55,2 55,2 Storage mode (VDC) 13,2 / 26,4 13,2 / 26,4 / 52,8 26,4 / 52,8 52,8 52,8 Charge current house battery (A)(4) 120 / 70 220 / 120 / 70 200 / 110 140 200 Charge current starter battery (A) 4 (12 V and 24 V models only) Battery temperature sensor Yes GENERAL Auxiliary output (A)(5) 25 50 50 50 50 Programmable relay(6) 3x 3x 3x 3x 3x Protection (2) a-g VE.Bus communication port For parallel and three phase operation, remote monitoring and system integration General purpose com. port 2x 2x 2x 2x 2x Remote on-off Yes Common Characteristics Operating temp.: -20 to +60 ˚C Humidity (non-condensing): max. 95 % Maximum altitude 3500 m ENCLOSURE Common Characteristics Material & Colour: aluminium (blue RAL 5012) Protection category: IP20, pollution degree 2, OVC III Battery-connection Four M8 bolts (2 plus and 2 minus connections) 230 VAC-connection Screw terminals 13 mm2 (6 AWG) Bolts M6 Bolts M6 Bolts M6 Bolts M6 Weight (kg) 19 34 / 30 / 30 45 / 41 51 72 Dimensions (hxwxd in mm) 362 x 258 x 218 470 x 350 x 280 444 x 328 x 240 444 x 328 x 240 470 x 350 x 280 470 x 350 x 280 572 x 488 x 344 STANDARDS Safety EN-IEC 60335-1, EN-IEC 60335-2-29, EN-IEC 62109-1 Emission, Immunity EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3, IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3 Road vehicles 12 V and 24 V models: ECE R10-4 Anti-islanding See our website 1) Can be adjusted to 60 HZ. 120 V models available on request 2) Protection key: a) output short circuit b) overload c) battery voltage too high d) battery voltage too low e) temperature too high f) 230 VAC on inverter output g) input voltage ripple too high 3) Non-linear load, crest factor 3:1 4) Up to 25 ˚C ambient 5) Switches off when no external AC source available 6) Programmable relay that can a.o. be set for general alarm, DC under voltage or genset start/stop function AC rating: 230 V / 4 A DC rating: 4 A up to 35 VDC, 1 A up to 60 VDC Digital Multi Control Panel A convenient and low cost solution for remote monitoring, with a rotary knob to set PowerControl and PowerAssist levels. Color Control GX and other GX devices Monitoring and control. Locally, and also remotely on the VRM Portal. MK3-USB (VE.Bus to USB interface) Connects to a USB port (see ‘A guide to VEConfigure’) VE.Bus to NMEA 2000 interface Connects the device to a NMEA 2000 marine electronics network. See the NMEA2 000 & MFD integration guide Computer controlled operation and monitoring Several interfaces are available: VE.Bus Smart Dongle Measures battery voltage and temperature and allows monitoring and control of Multis and Quattros with a smartphone or other Bluetooth enabled device. BMV-712 Smart Battery Monitor Use a smartphone or other Bluetooth enabled device to: - customize settings, - monitor all important data on single screen, - view historical data, and to update the software when new features become available.
RkJQdWJsaXNoZXIy MjM2MTk=