Victron

63 Victron Energy B.V. | De Paal 35 | 1351 JG Almere | The Netherlands E-mail: sales@victronenergy.com | www.victronenergy.com MultiPlus 12 Volt 24 Volt 12/2000/80 24/2000/50 12/3000/120 24/3000/70 PowerControl Yes PowerAssist Yes Transfer switch (A) 50 Parallel and 3-phase operation Yes INVERTER Input voltage range (V DC) 9,5 – 17 V 19 – 33 V Output Output voltage: 120 VAC ± 2% Frequency: 60 Hz ± 0,1% (1) Cont. output power at 25ºC / 77°F (VA)(3) 2000 3000 Cont. output power at 25ºC / 77°F (W) 1600 2400 Cont. output power at 40ºC / 104°F (W) 1450 2200 Cont. output power at 65ºC / 150°F (W) 1100 1700 Peak power (W) 4000 6000 Maximum efficiency (%) 92 / 94 93 / 94 Zero load power (W) 9 / 11 20 / 20 Zero load power in AES mode (W) 7 / 8 15 / 15 Zero load power in Search mode (W) 3 / 4 8 / 10 CHARGER AC Input Input voltage range: 95-140 VAC Input frequency: 45 –65 Hz Power factor: 1 Charge voltage 'absorption' (V DC) 14,4 / 28,8 Charge voltage 'float' (V DC) 13,8 / 27,6 Storage mode (V DC) 13,2 / 26,4 Charge current house battery (A)(4) 80 / 50 120 / 70 Charge current starter battery (A) 4 Battery temperature sensor yes GENERAL Auxiliary output(5) n. a. Yes (32A) Programmable relay (6) Yes (1x) Yes (3x) Protection(2) a - g VE.Bus communication port For parallel and three phase operation, remote monitoring and system integration General purpose com. port (7) n. a. Yes (2x) Remote on-off Yes Common Characteristics Operating temp. range: -40 - +65°C / -40 to 150°F (fan assisted cooling) Humidity (non-condensing): max 95% ENCLOSURE Common Characteristics Material & Colour: aluminium (blue RAL 5012) Protection category: IP 21 Battery-connection M8 bolts M8 bolts (2 plus and 2 minus connections) 120 V AC-connection Screw-terminal 6 AWG (13 mm²) Screw-terminal 6 AWG (13mm²) Weight 13 kg 25 lbs. 19kg 40 lbs. Dimensions (hxwxd in mm and inches) 520x255x125 mm 20.5x10.0x5.0 inch 362x258x218 mm 14.3x10.2x8.6 inch STANDARDS Safety UL 458, EN-IEC 60335-1, EN-IEC 60335-2-29 UL 1741, UL 458, EN-IEC 60335-1, EN-IEC 60335-2-29 Emission and Immunity EN-IEC 61000-3-2/3-3/, EN-IEC 61000-6-1/6-2/6-3 EN-IEC 61000-3-2/3-3/, EN-IEC 61000-6-1/6-2/6-3 1) Can be adjusted to 50 HZ; 2) Protection key: a) output short circuit b) overload c) battery voltage too high d) battery voltage too low e) temperature too high f) 120 VAC on inverter output g) input voltage ripple too high 3) Non-linear load, crest factor 3:1 4) Up to 75˚F ambient 5) Switches off when no external AC source available 6) Programmable relay that can a.o. be set for general alarm, DC under voltage or genset start/stop function AC rating: 120 V/4 A DC rating: 4 A up to 35 VDC, 1 A up to 60 VDC 7) A.o. to communicate with a Lithium Ion battery BMS Computer controlled operation and monitoring Several interfaces are available: Digital Multi Control A convenient and low cost solution for remote monitoring, with a rotary knob to set PowerControl and PowerAssist levels. VE.Bus Smart Dongle Measures battery voltage and temperature and allows monitoring and control of Multis and Quattros with a smartphone or other Bluetooth enabled device. Color Control GX and other GX devices Provides monitor and control. Locally, and also remotely on the VRM Portal. MK3-USB VE.Bus to USB interface Connects to a USB port (see ‘A guide to VEConfigure’) VE.Bus to NMEA 2000 interface Connects the device to a NMEA2000 marine electronics network. See the NMEA2000 & MFD integration guide BMV-712 Smart Battery Monitor Use a smartphone or other Bluetooth enabled device to: - customize settings, - monitor all important data on single screen, - view historical data, and to update the software when new features become available.

RkJQdWJsaXNoZXIy MjM2MTk=