61 Victron Energy B.V. | De Paal 35 | 1351 JG Almere | The Netherlands E-mail: sales@victronenergy.com | www.victronenergy.com MultiPlus 12 Volt 24 Volt 48 Volt C 12/800/35 C 24/ 800/16 C 12/1200/50 C 24/1200/25 C 12/1600/70 C 24/1600/40 C 12/2000/80 C 24/2000/50 12/3000/120 24/3000/70 48/3000/35 24/5000/120 48/5000/70 Nominal Battery voltage n. a. n. a. n. a. n. a. 12V battery 24V battery 48V battery 24V battery 48V battery PowerControl Yes Yes Yes Yes Yes Yes PowerAssist Yes Yes Yes Yes Yes Yes AC input Input voltage range: 187-250 V Input frequency: 50/60 Hz Cos Φ >0.8 Transfer switch (A) 16 16 16 30 16 or 50 100 INVERTER Input voltage range (VDC) 9,5 – 17 V 19 –33 V 38 – 66 V Input current (A DC) n. a. n. a. n. a. n. a. 250 / 125 / 65 238 /118 Output Output voltage: 230 VAC ± 2 % Frequency: 50 Hz ± 0,1 %(1) Cont. output power at 25 °C (VA) (3) 800 1200 1600 2000 3000 5000 Cont. output power at 25 °C (W) 700 1000 1300 1600 2400 4000 Cont. output power at 40 °C (W) 650 900 1200 1400 2200 3700 Cont. output power at 65 °C (W) 400 600 800 1000 1700 3000 Peak power (W) 1600 2400 3000 4000 6000 10.000 Maximum continuous Output current (A~) n. a. n. a. n. a. n. a. 11 19 Power factor range n. a. n. a. n. a. n. a. ±0.8 ±0.8 Maximum output fault current n. a. n. a. n. a. n. a. 32A peak 1 sec. 53A peak 1sec Maximum efficiency (%) 92 / 94 93 / 94 93 / 94 93 / 94 93 / 94 / 95 94 / 95 Zero load power (W) 8 / 10 8 / 10 8 / 10 9 / 11 20 / 20 / 25 30 / 35 Zero load power in AES mode (W) 5 / 8 5 / 8 5 / 8 7 / 9 15 / 15 / 20 25 / 30 Zero load power in Search mode (W) 2 / 3 2 / 3 2 / 3 3 / 4 8 / 10 / 12 10 / 15 CHARGER AC Input Input voltage range: 187-265 VAC Input frequency: 45 – 65 Hz Power factor: 1 Charge voltage 'absorption' (VDC) 14,4 / 28,8 / 57,6 Charge voltage 'float' (VDC) 13,8 / 27,6 / 55,2 Storage mode (VDC) 13,2 / 26,4 / 52,8 Charge current house battery (A)(4) 35 / 16 50 / 25 70 / 40 80 / 50 120 / 70 / 35 120 / 70 Charge current starter battery (A) 4 (12 V and 24 V models only) Battery temperature sensor yes GENERAL Auxiliary output (5) n. a. n. a. n. a. n. a. Yes (16A) Yes (50A) Programmable relay (6) Yes Protection (2) a - g VE.Bus communication port For parallel and three phase operation, remote monitoring and system integration General purpose com. port n. a. n. a. n. a. n. a. Yes Yes Remote on-off Yes Common Characteristics Operating temp. range: -40 to +65 °C (fan assisted cooling) Humidity (non-condensing): max 95 % ENCLOSURE Common Characteristics Material & Colour: aluminium (blue RAL 5012), Protection category: IP20, pollution degree 2, OVCIII Icw: 6kA 30mS Battery-connection battery cables of 1.5 meter M8 bolts Four M8 bolts (2 plus and 2 minus connections) 230 VAC-connection G-ST18i connector Spring-clamp Screw terminals 13 mm2 (6 AWG) M6 bolts Weight (kg) 10 10 10 12 18 30 Dimensions (hxwxd in mm) 375 x 214 x 110 520 x 255 x 125 362 x 258 x 218 444 x 328 x 240 STANDARDS Safety EN-IEC 60335-1, EN-IEC 60335-2-29, IEC 62109-1 Emission, Immunity EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3, IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3 Road vehicles 12 V and 24 V models: ECE R10-4 Anti-islanding See our website 1) Can be adjusted to 60 HZ. 120 V models available on request 2) Protection key: a) output short circuit b) overload c) battery voltage too high d) battery voltage too low e) temperature too high f) 230 VAC on inverter output g) input voltage ripple too high 3) Non-linear load, crest factor 3:1 4) Up to 25 ˚C ambient 5) Switches off when no external AC source available 6) Programmable relay that can a.o. be set for general alarm, DC under voltage or genset start/stop function AC rating: 230 V/4 A DC rating: 4 A up to 35 VDC, 1 A up to 60 VDC 7) A.o. to communicate with a Lithium Ion battery BMS VE.Bus Smart Dongle Measures battery voltage and temperature and allows monitoring and control of Multis and Quattros with a smartphone or other Bluetooth enabled device. Digital Multi Control Panel A convenient and low cost solution for remote monitoring, with a rotary knob to set PowerControl and PowerAssist levels. BMV-712 Smart Battery Monitor Use a smartphone or other Bluetooth enabled device to: - customize settings, - monitor all important data on single screen, - view historical data, and to update the software when new features become available. Color Control GX and other GX devices Monitoring and control. Locally, and also remotely on the VRM Portal. MK3-USB (VE.Bus to USB interface) Connects to a USB port (see ‘A guide to VEConfigure’) VE.Bus to NMEA 2000 interface Connects the device to a NMEA 2000 marine electronics network. See the NMEA 2000 & MFD integration guide Computer controlled operation and monitoring Several interfaces are available:
RkJQdWJsaXNoZXIy MjM2MTk=