59 Victron Energy B.V. | De Paal 35 | 1351 JG Almere | The Netherlands E-mail: sales@victronenergy.com | www.victronenergy.com VRM app for Wi-Fi Monitor and manage your Victron Energy system from your smart phone and tablet. Available for both iOS and Android. VRM Portal Our free remote monitoring website (VRM) will display all your system data in a comprehensive graphical format. System settings can be changed remotely via the portal. Alarms can be received by e-mail. Current sensor 100 A:50 mA To implement PowerControl and PowerAssist and to optimize self-consumption with external current sensing. Maximum current: 50 A resp. 100 A. Length of connection cable: 1 m. MultiPlus-II GX 24/3000/70-32 48/3000/35-32 48/5000/70-50 PowerControl & PowerAssist Yes Transfer switch 32A 50A Maximum AC input current 32A 50A Auxiliary output Yes (32 A) INVERTER DC Input voltage range 19 – 33 V 38 – 66 V Output Output voltage: 230 VAC ± 2 % Frequency: 50 Hz ± 0,1 % (1) Cont. output power at 25 °C (3) 3000VA 5000VA Cont. output power at 25 °C 2400W 4000W Cont. output power at 40 °C 2200W 3700W Cont. output power at 65 °C 1700W 3000W Maximum apparent feed-in power 3000VA 5000VA Peak power 5500W 9000W Maximum efficiency 94% 95% 96% Zero load power 13W 11W 18W Zero load power in AES mode 9W 7W 12W Zero load power in Search mode 3W 2W 2W CHARGER AC Input Input voltage range: 187-265 VAC Input frequency: 45 – 65 Hz Charge voltage 'absorption' 28,8V 57,6V Charge voltage 'float' 27,6V 55,2V Storage mode 26,4V 52,8V Maximum battery charge current (4) 70A 35A 70A Battery temperature sensor Yes GENERAL Interfaces BMS-Can, USB, Ethernet, VE.Direct, Wi-Fi External AC current sensor (optional) 50A 100A Programmable relay (5) Yes Protection (2) a –g VE.Bus communication port For parallel and three phase operation, remote monitoring and system integration General purpose com. port Yes, 2x Remote on-off Yes Operating temperature range -40 to +65 °C (fan assisted cooling) Humidity (non-condensing) max 95 % ENCLOSURE Material & Colour Steel, blue RAL 5012 Protection category IP22 Battery-connection M8bolts 230 V AC-connection Screw terminals 13 mm² (6 AWG) Weight 20kg 31kg Dimensions (hxwxd) mm 506 x 275 x 147 565 x 323 x 148 STANDARDS Safety EN-IEC 60335-1, EN-IEC 60335-2-29, EN-IEC 62109-1, EN-IEC 62109-2 Emission, Immunity EN 55014-1, EN 55014-2 EN-IEC 61000-3-2, EN-IEC 61000-3-3 IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3 Uninterruptible power supply IEC 62040-1 Anti-islanding Please consult the certificates on our website. 1) Can be adjusted to 60 Hz 2) Protection key: a) output short circuit b) overload c) battery voltage too high d) battery voltage too low e) temperature too high f) 230 VAC on inverter output g) input voltage ripple too high 3) Non-linear load, crest factor 3:1 4) Up to 25 °C ambient 5) Programmable relay which can be set for general alarm, DC under voltage or genset start/stop function. AC rating: 230 V / 4 A, DC rating: 4 A up to 35 VDC and 1 A up to 60 VDC Digital Multi Control Panel A convenient and low-cost solution for remote monitoring, with a rotary knob to set PowerControl and PowerAssist levels. Connection Area GX GSM A cellular modem; providing a mobile internet for the system and connection to Victron Remote Management (VRM). Optional: outdoor GSM antenna and GPS antenna. For more detail please enter GX GSMin the search box on our website
RkJQdWJsaXNoZXIy MjM2MTk=