57 Victron Energy B.V. | De Paal 35 | 1351 JG Almere | The Netherlands E-mail: sales@victronenergy.com | www.victronenergy.com Cerbo GX with GX Touch 50 Provides intuitive system control and monitoring Besides system monitoring and control the Cerbo enables access to our free remote monitoring website: the VRM Online Portal VRM app Monitor and manage your Victron Energy system from your smart phone and tablet. Available for both iOS and Android. VRM Portal Our free remote monitoring website (VRM) will display all system data in a comprehensive graphical format. System settings can be changed remotely via the portal. Alarms can be received by e-mail. Current sensor 100A:50mA To implement PowerControl and PowerAssist and to optimize selfconsumption with external current sensing. Maximum current: 50A resp. 100A. MultiPlus-II 2x120V 12/3000/120-50 24/3000/70-50 PowerControl & PowerAssist Yes (on L1 input) Transfer switch 50 A Maximum AC input current 50A (each leg) INVERTER DC Input voltage range 9,5 – 17 V 19-33V Output when in inverter mode Output voltage: 120 VAC ± 2% Frequency: 60 Hz ± 0,1% (1) Cont. output power at 25°C (3) 3000 VA Cont. output power at 25°C 2400 W Cont. output power at 40°C 2200 W Cont. output power at 65°C 1700 W Maximum apparent feed-in power 2500 VA Peak power 5500 W Maximum efficiency 93% 94% Zero load power 15W 11W Zero load power in AES mode 10W 8W Zero load power in Search mode 4W 4W CHARGER AC Input Split phase: 180-280 VAC 45 – 65 Hz Single phase: 90-140 VAC 45 – 65 Hz Charge voltage 'absorption' 14,4 V 28,8 V Charge voltage 'float' 13,8 V 27,6 V Storage mode 13,2 V 26,4 V Maximum battery charge current (4) 120 A 70 A Battery temperature sensor Yes GENERAL Auxiliary output (5) 50 A (each leg) See note 8 External AC current sensor (optional) 100 A Programmable relay (6) Yes Protection (2) a –g VE.Bus communication port For parallel and three phase operation, remote monitoring and system integration General purpose com. Port (7) Yes, 2x Remote on-off Yes Operating temperature range -40 to +65°C (-40 -150°F) Fan assisted cooling Humidity (non-condensing) max 95% ENCLOSURE Material & Colour Steel, blue RAL 5012 Protection category IP22 Battery-connection 2x2 M8 bolts 2 M8 bolts 120/240 V AC-connection Screw terminals 21 mm² (4 AWG) Weight 22 kg (48 lb) Dimensions (hxwxd) 578 x 275 x 148 mm (23 x 11 x 6 inch) 578 x 275 x 148 mm (23 x 11 x 6 inch) STANDARDS Safety EN-IEC 60335-1, EN-IEC 60335-2-29, UL 458 Emission, Immunity EN 55014-1, EN 55014-2 EN-IEC 61000-3-2, EN-IEC 61000-3-3 IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3 1) Can be adjusted to 50 Hz 2) Protection key: a) output short circuit b) overload c) battery voltage too high d) battery voltage too low e) temperature too high f) 120 VAC on inverter output g) input voltage ripple too high 3) Non-linear load, crest factor 3:1 4) Up to 75 ˚ F / 25 ˚ C ambient 5) Switches off when no external AC source available 6) Programmable relay that can a.o. be set for general alarm, DC under voltage or genset start/stop function AC rating: 120 V/4 A DC rating: 4 A up to 35 VDC, 1 A up to 60 VDC 7) A. o. to communicate with a Lithium-Ion battery BMS 8) The auxiliary output of an early production batch of this product was rated at 35A instead of 50A. This batch has serial numbers starting with HQ2107. Later batches, with 50A aux. output have serial numbers starting with HQ2114 or higher. Digital Multi Control Panel A convenient and low-cost solution for remote monitoring, with a rotary knob to set PowerControl and PowerAssist levels. VE.Bus Smart Dongle Measures battery voltage and temperature and allows monitoring and control with a smart phone or other Bluetooth enabled device. Connection Area
RkJQdWJsaXNoZXIy MjM2MTk=