Victron

55 Victron Energy B.V. | De Paal 35 | 1351 JG Almere | The Netherlands E-mail: sales@victronenergy.com | www.victronenergy.com GX Touch and Cerbo GX Provides intuitive system control and monitoring Besides system monitoring and control the Cerbo GX enables access to our free remote monitoring website: the VRM Online Portal VRM app Monitor and manage your Victron Energy system from your smart phone and tablet. Available for both iOS and Android. VRM Portal Our free remote monitoring website (VRM) will display all your system data in a comprehensive graphical format. System settings can be changed remotely via the portal. Alarms can be received by email. Current sensor 100A:50mA To implement PowerControl and PowerAssist and to optimize selfconsumption with external current sensing. Maximum current: 50A resp. 100A. Length of connection cable: 1 m. MultiPlus-II 230V 12/3000/120-32 24/3000/70-32 48/3000/35-32 24/5000/120-50 48/5000/70-50 48/8000/ 110-100 48/10000/ 140-100 48/15000/ 200-100 PowerControl & PowerAssist Yes Transfer switch 32 A 50 A 100 A 100 A 100 A Maximum AC input current 32 A 50 A 100 A 100 A 100 A INVERTER DC Input voltage range 12V - 9,5–17 V 24V - 19–33V 48V – 38-66 V Output Output voltage: 230 VAC ± 2% Frequency: 50 Hz ± 0,1% (1) Cont. output power at 25°C (3) 3000 VA 5000 VA 8000 VA 10000 VA 15000 VA Cont. output power at 25°C 2400 W 4000 W 6400 W 8000 W 12000 W Cont. output power at 40°C 2200 W 3700 W 5500 W 7000 W 10000 W Cont. output power at 65°C 1700 W 3000 W 4000 W 6000 W 7000 W Max apparent feed-in power 3000 VA 5000 VA 8000 VA 10000 VA 15000 VA Peak power 5500 W 9000 W 15000 W 18000 W 27000 W Maximum efficiency 93%/94%/95% 96% 95% 96% 95% Zero load power 13 / 13 / 11 W 18 W 29 W 38 W 55 W Zero load power in AES mode 9 / 9 / 7 W 12 W 19 W 27 W 39 W Zero load power in Search mode 3 / 3 / 2 W 2 W 3 W 4 W 6 W CHARGER AC Input Input voltage range: 187-265 VAC Input frequency: 45 – 65 Hz Charge voltage 'absorption' 14,4 / 28,8 / 57,6 V Charge voltage 'float' 13,8 / 27,6 / 55,2 V Storage mode 13,2 / 26,4 / 52,8 V Max.battery charge current (4) 120 /70 / 35 A 120 / 70 A 110 A 140 A 200 A Battery temperature sensor Yes GENERAL Auxiliary output Yes (32A) Yes (50A) External AC current sensor (optional) 50A or 100A Programmable relay (5) Yes Protection (2) a –g VE.Bus communication port For parallel (not for 8k, 10k and 15k models) and three phase operation, remote monitoring and system integration General purpose com. port Yes, 2x Remote on-off Yes Operating temperature range -40 to +65°C (fan assisted cooling) Humidity (non-condensing) max 95% ENCLOSURE Material & Colour Steel, blue RAL 5012 Protection category IP22 Battery-connection M8 bolts Four M8 bolts (2 plus and 2 minus connections) 230 V AC-connection Screw terminals 13 mm² (6 AWG) Bolts M6 Bolts M6 Bolts M6 Weight 19 kg 30 kg 42 kg 49 kg 80kg Dimensions (hxwxd) mm 546 x 275 x 147 499 x 268 x 141 499 x 268 x 141 607 x 330 x 149 565 x 320 x 149 642 x 363 x 206 677 x 363 x 206 810 x 405 x 217 STANDARDS Safety EN-IEC 60335-1, EN-IEC 60335-2-29, EN-IEC 62109-1, EN-IEC 62109-2 Emission, Immunity EN 55014-1, EN 55014-2 EN-IEC 61000-3-2, EN-IEC 61000-3-3 IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3 Uninterruptible power supply Please consult the certificates on our website. Anti-islanding Please consult the certificates on our website. 1) Can be adjusted to 60 Hz 2) Protection key: a) output short circuit b) overload c) battery voltage too high d) battery voltage too low e) temperature too high f) 230 VAC on inverter output g) input voltage ripple too high 3) Non-linear load, crest factor 3:1 4) Up to 25°C ambient 5) Programmable relay which can be set for general alarm, DC under voltage or genset start/stop function. AC rating: 230V / 4A, DC rating: 4A up to 35VDC and 1A up to 60VDC Digital Multi Control Panel A convenient and low-cost solution for remote monitoring, with a rotary knob to set PowerControl and PowerAssist levels. VE.Bus Smart Dongle Measures battery voltage and temperature and allows monitoring and control with a smart phone or other Bluetooth enabled device. Connection Area MultiPlus-II 3k

RkJQdWJsaXNoZXIy MjM2MTk=