Victron

51 Victron Energy B.V. | De Paal 35 | 1351 JG Almere | The Netherlands E-mail: sales@victronenergy.com www.victronenergy.com Inverter C12/1200 C24/1200 C12/1600 C24/1600 C12/2000 C24/2000 12/3000 24/3000 48/3000 24/5000 48/5000 Parallel and 3-phase operation Yes INVERTER Input voltage range (VDC) 9,5 – 17 V 19 – 33 V 38 – 66 V Output Output voltage: 230 VAC ± 2 % Frequency: 50 Hz ±0,1 % (1) Cont. output power at 25ºC (VA) (2) 1200 1600 2000 3000 5000 Cont. output power at 25ºC (W) 1000 1300 1600 2400 4000 Cont. output power at 40ºC (W) 900 1200 1450 2200 3700 Cont. output power at 65ºC (W) 600 800 1000 1700 3000 Peak power (W) 2400 3000 4000 6000 10000 Max. efficiency 12/ 24 / 48V (%) 92 / 94 92 / 94 92 / 92 93 / 94 / 95 94 / 95 Zero load power 12 / 24 / 48V (W) 8 / 10 8 / 10 9 / 11 20 / 20 / 25 30 / 35 Zero load power in AES mode (W) 5 / 8 5 / 8 7 / 9 15 / 15 / 20 25 / 30 Zero load power in Search mode (W) 2 / 3 2 / 3 3 / 4 8 / 10 / 12 10 / 15 GENERAL Programmable relay (3) Yes Protection (4) a -g VE.Bus communication port For parallel and three phase operation, remote monitoring and system integration Remote on-off Yes Common Characteristics Operating temperature range: -40 to +65ºC (fan assisted cooling) Humidity (non-condensing): max 95 % ENCLOSURE Common Characteristics Material & Colour: aluminium (blue RAL 5012) Protection category: IP21 Battery-connection battery cables of 1.5 meter included M8 bolts 2+2 M8 bolts 230 V AC-connection G-ST18i plug Spring-clamp Screw terminals Weight (kg) 10 12 18 30 Dimensions (hxwhd in mm) 375 x 214 x 110 520 x 255 x 125 362 x 258 x 218 444 x 328 x 240 STANDARDS Safety EN 60335-1 Emission Immunity EN 55014-1 / EN 55014-2 1) Can be adjusted to 60 Hz and to 240 V 2) Non-linear load, crest factor 3:1 3) Programmable relay that can a.o. be set for general alarm, DC under voltage or genset start/stop function. AC rating: 230 V /4 A DC rating: 4 A up to 35 VDC, 1 A up to 60VDC 4) Protection key: a) output short circuit b) overload c) battery voltage too high d) battery voltage too low e) temperature too high f) 230 VAC on inverter output g) input voltage ripple too high Computer controlled operation and monitoring Several interfaces are available: Inverter Control This panel can also be used on a MultiPlus Inverter/Charger when an automatic transfer switch but no charger function is desired. The brightness of the LEDs is automatically reduced during night time. BMV-700 Battery Monitor The BMV-700 Battery Monitor features an advanced microprocessor control system combined with high resolution measuring systems for battery voltage and charge/discharge current. Besides this, the software includes complex calculation algorithms, like Peukert’s formula, to exactly determine the state of charge of the battery. The BMV-700 selectively displays battery voltage, current, consumed Ah or time to go. The monitor also stores a host of data regarding performance and use of the battery. Several models available (see battery monitor documentation). VE.Bus to NMEA 2000 interface Connects the device to a NMEA 2000 marine electronics network. See the NMEA 2000 & MFD integration guide MK3-USB VE.Bus to USB interface Connects to a USB port (see ‘A guide to VEConfigure’) Color Control GX Provides monitor and control. Locally, and also remotely on the VRM Portal.

RkJQdWJsaXNoZXIy MjM2MTk=