Victron

49 Inverter 12 Volt 24 Volt 48 Volt 12/250 24/250 48/250 12/375 24/375 48/375 12/500 24/500 48/500 12/800 24/800 48/800 12/1200 24/1200 48/1200 Cont. power at 25°C (1) 250VA 375VA 500VA 800VA 1200VA Cont. power at 25°C / 40°C 200 / 175W 300 / 260W 400 / 350W 650 / 560W 1000 / 850W Peak power 400W 700W 900W 1500W 2200W Output AC voltage / frequency (adjustable) 230VAC or 120VAC +/- 3% 50Hz or 60Hz +/- 0,1% Input voltage range 9,2 - 17 / 18,4 - 34,0 / 36,8 - 62,0V DC low shut down (adjustable) 9,3 / 18,6 / 37,2V Dynamic (load dependent) DC low shut down (fully configurable) Dynamic cut-off, see https://www.victronenergy.com/live/ve.direct:phoenix-inverters-dynamic-cutoff DC low restart and alarm (adjustable) 10,9 / 21,8 / 43,6V Battery charged detect (adjustable) 14,0 / 28,0 / 56,0V Max. efficiency 87 / 88 / 88% 89 / 89 / 90% 90 / 90 / 91% 90 / 90 / 91% 91 / 91 / 92% Zero-load power 4,2 / 5,2 / 7,9W 5,6 / 6,1 / 8,5W 6 / 6,5 / 9W 6,5 / 7 / 9,5W 7 / 8 / 10W Default zero-load power in ECO mode (default retry interval: 2,5 s, adjustable) 0,8 / 1,3 / 2,5W 0,9 / 1,4 / 2,6W 1 / 1,5 / 3,0W 1 / 1,5 / 3,0W 1 / 1,5 / 3,0W ECO mode stop and start power setting Adjustable Protection (2) a - f Operating temperature range -40 to +65°C (fan assisted cooling) Derate 1,25% per °C above 40°C Humidity (non-condensing) max 95% ENCLOSURE Material & Colour Steel chassis and plastic cover (blue Ral 5012) Battery-connection Screw terminals Maximum cable cross-section 10mm² / AWG8 10mm² / AWG8 10mm² / AWG8 25/10/10mm² / AWG4/8 /8 35 / 25 / 25mm2 / AWG2/4 /4 Standard AC outlets 230V: Schuko (CEE 7/4), IEC-320 (male plug included) UK (BS 1363), AU/NZ (AS/NZS 3112) 120V: Nema 5-15R, GFCI Protection category IP 21 Weight 2,4kg / 5,3lbs 3,0kg / 6,6lbs 3,9kg / 8.5lbs 5,5kg / 12lbs 7,4kg / 16,3lbs Dimensions (h x w x d, mm) (h x w x d, inch) 86 x 165 x 260 3.4 x 6.5 x 10.2 86 x 165 x 260 3.4 x 6.5 x 10.2 86 x 172 x 275 3,4 x 6,8 x 10,8 105 x 216 x 305 4.1 x 8.5 x 12.1 (12V model: 105 x 230 x 325) 117 x 232 x 327 4.6 x 9.1 x 12.9 (12V model: 117 x 232 x 362) ACCESSORIES Remote on-off Yes Automatic transfer switch Filax STANDARDS Safety EN-IEC 60335-1 / EN-IEC 62109-1 / UL 458(3) EMC EN 55014-1 / EN 55014-2 / IEC 61000-6-1 / IEC 61000-6-2 / IEC 61000-6-3 Automotive Directive ECE R10-4 1) Nonlinear load, crest factor 3:1 2) Protection key: a) output short circuit b) overload c) battery voltage too high d) battery voltage too low e) temperature too high f) DC ripple too high 3) UL 458 only for inverters with GFCI output socket Battery Alarm An excessively high or low battery voltage is indicated by an audible and visual alarm, and a relay for remote signalling. BMV Battery Monitor The BMV Battery Monitor features an advanced microprocessor control system combined with high resolution measuring systems for battery voltage and charge/discharge current. Besides this, the software includes complex calculation algorithms to exactly determine the state of charge of the battery. The BMV selectively displays battery voltage, current, consumed Ah or time to go. The monitor also stores a host of data regarding performance and use of the battery. VE.Direct Bluetooth Smart dongle (must be ordered separately)

RkJQdWJsaXNoZXIy MjM2MTk=