113 Victron Energy B.V. | De Paal 35 | 1351 JG Almere | The Netherlands + - Domestic Battery Bank Cyrix-i + - Starter Battery GND Max 400A 0.1A Start Assist NC NO COM Charger Alternator Dynamo Starter Motor Battery 1 Battery 2 0 Profile Select Switch Remove cover to access Profile 0 Connect (V)* Disconnect (V)* Less than13 V Remains open More than 12,8 V Remains closed Closes after Opens after 13V 10 min 12,8V 10 min 13,2V 5 min 12,4V 5 min 13,4V 3 min 12,2V 1 min 13,6V 1 min 12V 4 sec 13,8V 4 sec Less than 11 V Immediate INVERTER Profile 1 Connect (V)* Disconnect (V)* Less than13,25 V Remains open More than 12,75 V Remains closed More than 13,25 V Closes after 30 sec From 10,5 V to 12,75 V Opens after 2 min Less than 10,5 V Immediate Profile 2 Connect (V)* Disconnect (V)* Less than13,2 V Remains open More than 12,8 V Remains closed More than 13,2 V Closes after 6 sec From 10,5 V to 12,8 V Opens after 30sec Less than 10,5 V Immediate Profile 3 Connect (V)* Disconnect (V)* Less than13,25 V Remains open More than 13,5 V Remains closed Closes after Opens after 13V 10 min 12,8V 30 min 13,2V 5 min 12,4V 12 min 13,4V 3 min 12,2V 2 min 13,6V 1 min 12V 1 min 13,8V 4 sec Less than 10,5 V Immediate NOTES 1) After connecting 3 times, the minimum time to reconnect is 1 minute (to prevent ‘rattling’) 2) The Cyrix will not connect if the voltage on one of the battery connections is less than 2 V*. (to prevent unexpected switching during installation) 3) The Cyrix will always connect if the start assist is activated, as long as the voltage on one of the battery connections is sufficient to operate the Cyrix (approximately 10 V*) * Multiply voltage x2 for 24 V systems and x4 for 48 V systems