109 ??????? www.victronenergy.com Victron Energy B.V. | De Paal 35 | 1351 JG Almere | The Netherlands E-mail: sales@victronenergy.com | www.victronenergy.com Connector with preassembled DC minus cable (included) Smart BatteryProtect 12/24 V 65 A/100 A/220 A Protects the battery against excessive discharge and can be used as a system on/off switch The Smart BatteryProtect disconnects the battery from non-essential loads before it is completely discharged (which would damage the battery) or before it has insufficient power left to crank the engine. The on/off input can be used as a system on/off switch. 12/24 V auto ranging The Smart BatteryProtect automatically detects system voltage one time only. Bluetooth: programming made easy When using Bluetooth to program the Smart BatteryProtect any required engage/disengage levels can be set. Alternatively, one of nine predefined engage/disengage levels can be set with the programming pin (see manual). If required, Bluetooth can be disabled. Instant Readout VictronConnect can display the most important data of the Smart BatteryProtect on the Device List page without the need to pair with the product. This includes visual notifications of warnings, alarms, and errors that enable diagnostics at a glance. A special setting for Li-ion batteries In this mode the BatteryProtect can be controlled by the VE.Bus BMS. Note: the BatteryProtect can also be used as a charge interrupter in between a battery charger and a Li-ion battery. See connection diagram in the manual. Ultra-low current consumption This is important in case of Li-ion batteries, especially after low voltage shutdown. Please see our Li-ion battery datasheet and the VE.Bus BMS manual for more information. Over voltage protection To prevent damage to sensitive loads due to over voltage, the load is disconnected whenever the DC voltage exceeds 16.3V respectively 32.6V. Ignition proof No relays but MOSFET switches, and therefore no sparks. Delayed alarm output The alarm output is activated if the battery voltage drops below the preset disconnect level during more than 12 seconds. Starting the engine will therefore not activate the alarm. The alarm output is a short circuit proof open collector output to the negative (minus) rail, max. current 50 mA. The alarm output is typically used to activate a buzzer, LED or relay. Delayed load disconnect and delayed reconnect The load will be disconnected 90 seconds after the battery voltage drops below the preset level. If the battery voltage increases again to the connect threshold within this time period (after the engine has been started for example), the load will not be disconnected. The load will be reconnected 30 seconds after the battery voltage has increased to more than the preset reconnect voltage. Smart BatteryProtect Smart BP-65 Smart BP-100 Smart BP-220 Maximum continuous load current* 65A 100A 220A Peak current (during 30 seconds) 250A 600A 600A Operating voltage range 6 –35 V Current consumption BLE On When on: 1,4 mA When off or low voltage shutdown: 0,9 mA BLE Off When on: 1,2 mA When off or low voltage shutdown: 0,7 mA Alarm output delay 12seconds Maximum load on alarm output 50 mA (short circuit proof) Load disconnect delay 90 seconds (immediate if triggered by the VE.Bus BMS) Load reconnect delay 30 seconds Default thresholds Disengage: 10,5 V or 21 V Engage: 12 V or 24 V Operating temperature range Full load: -40°C to +40°C (up to 60% of nominal load at 50°C) IP rating Electronics: IP67 (potted) Connections: IP00 Connection M6 M8 M8 Mounting Torque 5 Nm 9 Nm 9 Nm Weight 0,2 kg 0.5 lbs 0,5kg 0.6lbs 0,8 kg 1.8 lbs Dimensions (hxwxd) 48 x 55 x 106 mm 1.9 x 2.2 x 4.2 inch 61 x 41 x 164 mm 2.4 x 1.6 x 6.5 inch 60 x 123 x 121 mm 2.4 x 4.8 x 4.8 inch * The BatteryProtect is not designed for reverse currents from charging sources Bluetooth enabled System on-off switch Smart BatteryProtectBP-220 Smart BatteryProtect BP-65 Smart BatteryProtect BP-100 Instant Readout via VictronConnect SMART BATTERYPROTECT 12/24V 65A/100A/220A
RkJQdWJsaXNoZXIy MjM2MTk=