Victron-Energy
63 Energy. Anytime. Anywhere. Victron Energy B.V. | De Paal 35 | 1351 JG Almere | The Netherlands Isolated converters 220 - 280 Watt Orion-Tr 12/12-18 (220W) Orion-Tr 12/24-10 (240W) Orion-Tr 24/12-20 (240W) Orion-Tr 24/24-12 (280W) Orion-Tr 24/48-6 (280W) Orion-Tr 48/12-20 (240W) Orion-Tr 48/24-12 (280W) Orion-Tr 48/48-6 (280W) Input voltage range 8-17V 8-17V 16-35V 16-35V 16-35V 32-70V 32-70V 32-70V Under voltage shut down 7V 7V 14V 14V 14V 28V 28V 28V Under voltage restart 7,5V 7,5V 15V 15V 15V 30V 30V 30V Nominal output voltage 12,2V 24,2V 12,2V 24,2V 48,2V 12,2V 24,2V 48,2V Output voltage adjust range 10-15V 20-30V 10-15V 20-30V 40-60V 10-15V 20-30V 40-60V Output voltage tolerance +/- 0,2V Output noise 2mV rms Cont. output current at nominal output voltage and 40 ° C 18A 10A 20A 12A 6A 20A 12A 6A Maximum output current (10 s) at nominal output voltage 25A 15A 25A 15A 8A 25A 15A 8A Short circuit output current 40A 25A 50A 30A 25A 50A 30A 25A Cont. output power at 25 ° C 280W 280W 300W 320W 320W 280W 320W 320W Cont. output power at 40 ° C 220W 240W 240W 280W 280W 240W 280W 280W Efficiency 87% 88% 88% 89% 89% 87% 89% 89% Off load current < 80mA < 100mA < 100mA < 80mA < 120 mA < 80mA < 80mA < 80mA Galvanic isolation 200V dc between input, output and case Operating temperature range -20 to +55°C (derate 3% per °C above 40°C) Humidity Max. 95% non-condensing DC connection Screw terminals Maximum cable cross-section 16 mm² AWG6 Weight 1,3 kg (3 lb) Dimensions hxwxd 130 x 186 x 70 mm (5.1 x 7.3 x 2.8 inch) Standards: Safety Emission Immunity Automotive Directive EN 60950 EN 61000-6-3, EN 55014-1 EN 61000-6-2, EN 61000-6-1, EN 55014-2 ECE R10-5 Isolated converters 360 - 400 Watt Orion-Tr 12/12-30 (360W) Orion-Tr 12/24-15 (360W) Orion-Tr 24/12-30 (360W) Orion-Tr 24/24-17 (400W) Orion-Tr 24/48-8,5 (400W) Orion-Tr 48/12-30 (360W) Orion-Tr 48/24-16 (380W) Orion-Tr 48/48-8 (380W) Input voltage range 10-17V 10-17V 20-35V 20-35V 20-35V 40-70V 40-70V 40-70V Under voltage shut down 7V 7V 14V 14V 14V 28V 28V 28V Under voltage restart 7,5V 7,5V 15V 15V 15V 30V 30V 30V Nominal output voltage 12,2V 24,2V 12,2V 24,2V 48,2V 12,2V 24,2V 48,2V Output voltage adjust range 10-15V 20-30V 10-15V 20-30V 40-60V 10-15V 20-30V 40-60V Output voltage tolerance +/- 0,2V Output noise 2mV rms Cont. output current at nominal output voltage and 40 ° C 30A 15A 30A 17A 8,5A 30A 16A 8A Maximum output current (10 s) at nominal output voltage minus 20% 40A 25A 45A 25A 15A 40A 25A 15A Short circuit output current 60A 40A 60A 40A 25A 60A 40A 25A Cont. output power at 25 ° C 430W 430W 430W 480W 480W 430W 430W 430W Cont. output power at 40 ° C 360W 360W 360W 400W 400W 360W 380W 380W Efficiency 87% 88% 88% 89% 89% 87% 89% 89% Off load current < 80mA < 100mA < 100mA < 80mA < 120 mA < 80mA < 80mA < 80mA Galvanic isolation 200V dc between input, output and case Operating temperature range -20 to +55°C (derate 3% per °C above 40°C) Humidity Max. 95% non-condensing DC connection Screw terminals Maximum cable cross-section 16 mm² (AWG6) Weight 12V input and/or 12V output models: 1,8 kg (3 lb) Other models: 1,6 kg (3.5 lb) Dimensions hxwxd 12V input and/or 12V output models: 130 x 186 x 80 mm (5.1 x 7.3 x 3.2 inch) Other models: 130 x 186 x 70 mm (5.1 x 7.3 x 2.8 inch) Standards: Safety Emission Immunity Automotive Directive EN 60950 EN 61000-6-3, EN 55014-1 EN 61000-6-2, EN 61000-6-1, EN 55014-2 ECE R10-5
Made with FlippingBook
RkJQdWJsaXNoZXIy MjM2MTk=