Victron-Energy

33 Energy. Anytime. Anywhere. Quattro 12/3000/120-50/50 24/3000/70-50/50 12/5000/220-100/100 24/5000/120-100/100 48/5000/70-100/100 24/8000/200-100/100 48/8000/110-100/100 48/10000/140- 100/100 48/15000/200- 100/100 PowerControl / PowerAssist Yes Integrated Transfer switch Yes AC inputs (2x) Input voltage range: 187-265 VAC Input frequency: 45 – 65 Hz Power factor: 1 Maximum feed through current (A) 2x 50 2x100 2x100 2x100 2x100 INVERTER Input voltage range (V DC) 9,5 – 17V 19 – 33V 38 – 66V Output (1) Output voltage: 230 VAC ± 2% Frequency: 50 Hz ± 0,1% Cont. output power at 25°C (VA) (3) 3000 5000 8000 10000 15000 Cont. output power at 25°C (W) 2400 4000 6500 8000 12000 Cont. output power at 40°C (W) 2200 3700 5500 6500 10000 Cont. output power at 65°C (W) 1700 3000 3600 4500 7000 Peak power (W) 6000 10000 16000 20000 25000 Maximum efficiency (%) 93 / 94 94 / 94 / 95 94 / 96 96 96 Zero load power (W) 20 / 20 30 / 30 / 35 45 / 50 55 80 Zero load power in AES mode (W) 15 / 15 20 / 25 / 30 30 / 30 35 50 Zero load power in Search mode (W) 8 / 10 10 / 10 / 15 10 / 20 20 30 CHARGER Charge voltage 'absorption' (V DC) 14,4 / 28,8 14,4 / 28,8 / 57,6 28,8 / 57,6 57,6 57,6 Charge voltage 'float' (V DC) 13,8 / 27,6 13,8 / 27,6 / 55,2 27,6 / 55,2 55,2 55,2 Storage mode (V DC) 13,2 / 26,4 13,2 / 26,4 / 52,8 26,4 / 52,8 52,8 52,8 Charge current house battery (A) (4) 120 / 70 220 / 120 / 70 200 / 110 140 200 Charge current starter battery (A) 4 (12V and 24V models only) Battery temperature sensor Yes GENERAL Auxiliary output (A) (5) 25 50 50 50 50 Programmable relay (6) 3x 3x 3x 3x 3x Protection (2) a-g VE.Bus communication port For parallel and three phase operation, remote monitoring and system integration General purpose com. port 2x 2x 2x 2x 2x Remote on-off Yes Common Characteristics Operating temp.: -40 to +65˚C Humidity (non-condensing): max. 95% ENCLOSURE Common Characteristics Material & Colour: aluminium (blue RAL 5012) Protection category: IP 21 Battery-connection Four M8 bolts (2 plus and 2 minus connections) 230 V AC-connection Screw terminals 13 mm 2 (6 AWG) Bolts M6 Bolts M6 Bolts M6 Bolts M6 Weight (kg) 19 34 / 30 / 30 45 / 41 51 72 Dimensions (hxwxd in mm) 362 x 258 x 218 470 x 350 x 280 444 x 328 x 240 444 x 328 x 240 470 x 350 x 280 470 x 350 x 280 572 x 488 x 344 STANDARDS Safety EN-IEC 60335-1, EN-IEC 60335-2-29, EN-IEC 62109-1 Emission, Immunity EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3, IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3 Road vehicles 12V and 24V models: ECE R10-4 Anti-islanding See our website 1) Can be adjusted to 60 HZ; 120 V 60 Hz on request 2) Protection key: a) output short circuit b) overload c) battery voltage too high d) battery voltage too low e) temperature too high f) 230 VAC on inverter output g) input voltage ripple too high 3) Non-linear load, crest factor 3:1 4) At 25˚C ambient 5) Switches off when no external AC source available 6) Programmable relay that can a.o. be set for general alarm, DC under voltage or genset start/stop function AC rating: 230 V / 4 A DC rating: 4 A up to 35 VDC, 1 A up to 60 VDC Digital Multi Control Panel A convenient and low cost solution for remote monitoring, with a rotary knob to set PowerControl and PowerAssist levels. Blue Power Panel Connects to a Multi or Quattro and all VE.Net devices, in particular the VE.Net Battery Controller. Graphical display of currents and voltages. BMV-700 Battery Monitor The BMV-700 Battery Monitor features an advanced microprocessor control system combined with high resolution measuring systems for battery voltage and charge/discharge current. Besides this, the software includes complex calculation algorithms, like Peukert’s formula, to exactly determine the state of charge of the battery. The BMV-700 selectively displays battery voltage, current, consumed Ah or time to go. Color Control GX Monitoring and control. Locally, and also remotely on the VRM Portal. MK3-USB VE.Bus to USB interface Connects to a USB port (see ‘A guide to VEConfigure’ ) VE.Bus to NMEA 2000 interface Connects the device to a NMEA2000 marine electronics network. See the NMEA2000 & MFD integration guide Computer controlled operation and monitoring Several interfaces are available:

RkJQdWJsaXNoZXIy MjM2MTk=