Victron-Energy
25 Energy. Anytime. Anywhere. Victron Energy B.V. | De Paal 35 | 1351 JG Almere | The Netherlands General phone: +31 (0)36 535 97 00 | Fax: +31 (0)36 535 97 40 Phoenix Inverter C12/1200 C24/1200 C12/1600 C24/1600 C12/2000 C24/2000 12/3000 24/3000 48/3000 24/5000 48/5000 Parallel and 3-phase operation Yes INVERTER Input voltage range (V DC) 9,5 – 17V 19 – 33V 38 – 66V Output Output voltage: 230 VAC ± 2% Frequency: 50 Hz ± 0,1% (1) Cont. output power at 25 º C (VA) (2) 1200 1600 2000 3000 5000 Cont. output power at 25 º C (W) 1000 1300 1600 2400 4000 Cont. output power at 40 º C (W) 900 1200 1450 2200 3700 Cont. output power at 65 º C (W) 600 800 1000 1700 3000 Peak power (W) 2400 3000 4000 6000 10000 Max. efficiency 12/ 24 /48 V (%) 92 / 94 / 94 92 / 94 / 94 92 / 92 93 / 94 / 95 94 / 95 Zero load power 12 / 24 / 48 V (W) 8 / 10 / 12 8 / 10 / 12 9 / 11 20 / 20 / 25 30 / 35 Zero load power in AES mode (W) 5 / 8 / 10 5 / 8 / 10 7 / 9 15 / 15 / 20 25 / 30 Zero load power in Search mode (W) 2 / 3 / 4 2 / 3 / 4 3 / 4 8 / 10 / 12 10 / 15 GENERAL Programmable relay (3) Yes Protection (4) a - g VE.Bus communication port For parallel and three phase operation, remote monitoring and system integration Remote on-off Yes Common Characteristics Operating temperature range: -40 to +65 º C (fan assisted cooling) Humidity (non-condensing): max 95% ENCLOSURE Common Characteristics Material & Colour: aluminium (blue RAL 5012) Protection category: IP 21 Battery-connection battery cables of 1.5 meter included M8 bolts 2+2 M8 bolts 230 V AC-connection G-ST18i plug Spring-clamp Screw terminals Weight (kg) 10 12 18 30 Dimensions (hxwhd in mm) 375x214x110 520x255x125 362x258x218 444x328x240 STANDARDS Safety EN 60335-1 Emission Immunity EN 55014-1 / EN 55014-2 1) Can be adjusted to 60 Hz and to 240 V 2) Non-linear load, crest factor 3:1 3) Programmable relay that can a.o. be set for general alarm, DC under voltage or genset start/stop function. AC rating: 230 V / 4 A DC rating: 4 A up to 35 VDC, 1A up to 60VDC 4) Protection key: a) output short circuit b) overload c) battery voltage too high d) battery voltage too low e) temperature too high f) 230 V AC on inverter output g) input voltage ripple too high Computer controlled operation and monitoring Several interfaces are available: Phoenix Inverter Control This panel can also be used on a MultiPlus Inverter/Charger when an automatic transfer switch but no charger function is desired. The brightness of the LEDs is automatically reduced during night time. BMV-700 Battery Monitor The BMV-700 Battery Monitor features an advanced microprocessor control system combined with high resolution measuring systems for battery voltage and charge/discharge current. Besides this, the software includes complex calculation algorithms, like Peukert’s formula, to exactly determine the state of charge of the battery. The BMV-700 selectively displays battery voltage, current, consumed Ah or time to go. The monitor also stores a host of data regarding performance and use of the battery. Several models available (see battery monitor documentation). VE.Bus to NMEA 2000 interface Connects the device to a NMEA 2000 marine electronics network. See the NMEA 2000 & MFD integration guide MK3-USB VE.Bus to USB interface Connects to a USB port (see ‘A guide to VEConfigure’) Color Control GX Provides monitor and control. Locally, and also remotely on the VRM Portal.
Made with FlippingBook
RkJQdWJsaXNoZXIy MjM2MTk=