Osculati - Master Catalogue 2025 - ENG

238 Electrical material 14 \ 14.267.01/02 \ 14.270.30 \ 14.270.37 \ 14.270.33 \ 14.100.06 VICTRON TG microprocessor battery charger 3-stage IUOU charge with microprocessor that perfectly adapts the charge to the battery requirements (very important function in case of sealed batteries). Two isolated outlets, the second (4 A) dedicated to the starting batteries. Battery temperature compensation automatic system (it extends the life of sealed batteries). Technical Data: aluminium casing, internal temperature sensors + battery temperature sensor, forced ventilation, protection against short circuit, polarity reversal, overheating. Code Model Type V Frequency (Hz) V output / input Max charging current A Number of outputs Recommended for batteries A·h mm 14.267.01 TG 24/30 120- 230 45/65 28.5 / 230VAC 30 + 4 1 + 1 150/300 365 x 250 x 147 5.5 14.267.02 TG 24/50 120- 230 45/65 28.5 / 230VAC 50 + 4 1 + 1 250/500 365 x 250 x 147 5.5 14.267.12* TG (GMDSS) 24/50 120230 45/65 28.5 / 230VAC 50 + 4 1 + 1 250/500 485 x 250 x 147 6 14.267.30 TG 24/80 230 45/65 28.5 / 230VAC 80 + 4 1 + 1 400/800 365 x 250 x 257 10 14.267.31 TG 24/100 230 45/65 28.5 / 230VAC 100 + 4 1 + 1 500/1000 365 x 250 x 257 10 * Integrated battery control device included. 14.100.06 BMV-700 Battery monitor 14.270.33 Remote chargeswitch 14.270.30 Battery alarm panel: audio/visual alarm in case of high/low voltage. 14.270.37 SKYLLA control panel. It monitors the charge level and enables to reduce outlet AC current if the inlet AC power is low. \ 14.267.03/04 \ 14.267.05/06 \ 14.100.06 \ 14.270.47 \ 14.270.38 VICTRON Skylla-i 24 V microprocessor battery charger - Synchronised operation for multiple batteries in parallel via CANbus function; - Battery voltage detection to compensate for voltage losses caused by cable resistance; - The right amount of charge: variable absorption time. - BatterySafe mode: preventing damage due to excessive gassing. - Less maintenance and ageing when the battery is not needed: storage mode; - Temperature compensation to extend the battery life. - 185-265 VAC supply. - Provision for possible Li-ion battery charger (Life 904). Code Model Type V output/ input Max charging current A Number of outputs Recommended for batteries A·h mm 14.267.03 Skylla-i 24/80 28.8 80 3 400/800 402x250x140 8 14.267.05* Skylla-i 24/80 28.8 80+4 1+1 400/800 402x250x140 8 14.267.04 Skylla-i 24/100 28.8 100 3 500/1000 402x250x140 8 14.267.06* Skylla-i 24/100 28.8 100+4 1+1 500/1000 402x250x140 8 * 2 independent outputs: first full charge 80/100 A, second charge 4 A dedicated to starting batteries. 14.100.06 BMV-700 Battery monitor 14.270.XX RJ45 cables from 2 to 20 m. 14.270.38 SKYLLA-I control panel. It monitors the charge level and enables to reduce outlet current if the inlet power is low. Cable RJ45 required. \ 14.270.38 \ 14.100.06 \ 14.100.07 VICTRON Skylla IP65 microprocessor charger IP65 Splash-proof version resistant to splashes. Charges at 3 IUoUo stands with a microprocessor that perfectly adapts the type of charge required by the battery. Three independent outputs for charging multiple batteries together. Automatic temperature compensation system with internal sensors, forced ventilation, electronic board protection with acrylic resin, protection against short circuits, overvoltage, polarity reversal. Cable voltage drop compensation. Mode battery-safe: If opting for a high charge current and a higher absorption voltage to shorten charging times, SKYLLA will prevent gassing damage by automatically limiting the rate of voltage increase. Mode storage: If the battery does not work for 24 hours, the holding voltage is reduced to 2.2 V/ cell, minimizing gas formation. The voltage is reset to "absorption" level once a week to restore the battery. This function prevents sulfation and stratification of the electrolyte. Perfect voltage control makes the charger usable as a power supply. CANbus interface, with the ability to parallel multiple chargers via RJ45 cable. LCD control panel. Code IP Type V output/ input Charging Voltage (Absorption) V Max charging current A Number of outputs mm 14.267.20 65 12/70/3 90/265 14.4 70 3 401x300x165 6 14.267.21 65 24/35/3 90/265 28.8 35 3 401x300x165 6 14.100.06 BMV-700 Control panel for 1 battery. 14.100.07 BMV-702 Control panel for 2 batteries. 14.270.38 SKYLLA-I control panel. It monitors the charge level and enables to reduce outlet current if the inlet power is low.

RkJQdWJsaXNoZXIy MjM2MTk=