221 Electrical materials 14 E14.100.06 E14.100.07 E14.100.08 VICTRON battery monitor This digital monitor displays the status of any battery: voltage, state of charge (Ah or %), time to go, charge/discharge current, current and ampere-hours consumed and instant consumption. Visual and audible alarm. It comes with connection cables and shunt. VICTRONCode Model Version Monitor for V Bore Ø mm 14.100.06 BMV-700 Standard 1 battery 9/90 52 14.100.07* BMV-702 Standard 2 batteries/battery arrays 9/90 52 14.100.08 BMV-712 Standard + Bluetooth connection to smartphones and tablets 2 batteries/battery arrays 9/90 52 * It stores previous events to evaluate the battery conditions. Programmable relay to disconnect the power supply (with low battery) from non-essential services or to activate the generator. E14.268.18/19 E14.270.32 E14.100.06 VICTRON MULTIPLUS battery charger + inverter combo system This system combines a pure sine wave inverter and a sophisticated battery charger using adjustable recharge technology. Compatible with lithium batteries. Two AC outlets. In case of power shortage from the dock or from the generator, the system continuously feeds what’s connected. The second outlet is available in case of AC source, only. The devices, such as boilers, which might run the battery down should be connected to this outlet. Parallel + three-phase function. Up to 6 units can be connected in parallel. For the three-phase current, 3 units of the same kind can be connected. Up to 6 series of 3 units each can be connected in parallel. Power control: the very powerful multiplus device can absorb a lot of power from the dock or the generator. By means of the multicontrol panel (14.270.32), the current draw can be monitored and a maximum limit can be set. Depending on the limit set, the multiplus device will only use the remaining energy to charge the batteries. Power assist: whenever a power peak is required for a short period, the multiplus device will offset the power shortage drawing energy from the battery. When the current draw drops, the surplus current is used to recharge the batteries. The micro-processor operated battery charger is fitted with a 4-stage bulk-absorption-float-storage charge system similar to the Phoenix/Skylla battery chargers. - Aluminium body - Protection devices against short circuit, overcharge, too low or too high battery, high ripple frequency, etc. VICTRONCode Type DC supply V Inverter Power W Outlet V Battery charge current A No of outlets mm 14.268.00 12/500/20-16 9.5 - 17 500 230VDC ± 2% 20+1 1+1* 311x182x100 4.4 14.268.01 12/800/35 9.5 - 17 800 230VDC ± 2% 35+4 1+1* 360x240x100 6.4 14.268.02 12/1200/50 9.5 - 17 1200 230VDC ± 2% 50+4 1+1* 406x250x100 8.2 14.268.23 12/1600/70 9.5 - 17 1600 230VDC ± 2% 70+4 1+1* 465x270x120 10 14.268.26 24/1600/40 19 - 33 1600 230VDC ± 2% 40+4 1+1* 465x270x120 10 14.268.07 12/2000/80 9.5 - 17 2000 230VDC ± 2% 80+4 1+1* 520x255x125 12 14.268.09 24/2000/50 19 - 33 2000 230VDC ± 2% 50+4 1+1* 520x255x125 12 14.268.18** 24/3000/70-32 19 - 33 3000 230VDC ± 2% 70+4 1+1* 362x258x218 18 14.268.19 24/5000/120-100 19 - 33 5000 230VDC ± 2% 120+4 1+1* 444x328x240 30 * 1/4A second outlet for starter battery maintenance. ** 50A max commutable AC. 14.270.28 VE-Direct --> USB interface for computer connection (only for 14.268.00). 14.270.39 VE-Bus --> USB interface for computer connection. 14.270.32 Digital Multicontrol. Control panel for both inverter and battery charger. Inlet current management when switching from dock to generator. Triphase devices or devices in parallel can be managed. VE-BUS remote systems can be configured. RJ45 cord required. 14.270.47 RJ45 7-m cord to complete 14.270.39. 14.100.06 Battery monitor. 14.070.50 Color Control GX. E14.268.07/09 E14.268.00 E 14.070.50 E14.270.39 E14.270.47 E14.270.28
RkJQdWJsaXNoZXIy MjM2MTk=