Attwood

attwoodmarine.com 10 WATER SYSTEMS Wire Length for all models 29-1/2" (750mm). *Must be used with appropriate Sahara outlet. Model No. Rated Volts DC Fuse Size Outlet Type Check Valve OEM Part # OEM Outlet Straight OEM Outlet 90° Part # S500 12V 3A 3/4" (19mm) & 1" (25mm) Barbs Yes — — — 5505-7 3/4" (19mm) Barb No 5505-2 — — — 1-3/8" Threaded* Optional 5505-1 AS5505S-1 AS5505E-1 — S800 12V 4A 3/4" (19mm) & 1" (25mm) Barbs Yes — — — 5508-7 3/4" (19mm) Barb No 5508-2 — — — 1-3/8" Threaded* Optional 5508-1 AS5505S-1 AS5505E-1 — 24V 2A 3/4" (19mm) & 1" (25mm) Barbs Yes — — — 5509-7 3/4" (19mm) Barb No 5509-2 — — — 1-3/8" Threaded* Optional 5509-1 AS5505S-1 AS5505E-1 — S1200 12V 6A 1" (25mm) & 1-1/8" (28mm) Barbs Yes — — — 5512-7 1-1/8" (28mm) Barb No 5512-2 — — — 1-3/8" Threaded* Optional 5512-1 AS5512S-1 AS5512E-1 — 24V 2A 1" (25mm) & 1-1/8" (28mm) Barbs Yes — — — 5513-7 1-1/8" (28mm) Barb No 5513-2 — — — 1-3/8" Threaded* Optional 5513-1 AS5512S-1 AS5512E-1 — Mounting Pattern Compatibility Rulemate (Old) Johnson Ultima Sahara Mk1 Rulemate (New)/DA/SA Shoreline Johnson Float 5505 5509 5512 Service Kits: • AK5505-7 for S500 and S800 • AK5512-7 for S1200 • Service kits for Barb versions not available 12 Volt Specifications Model Automotive Fuse Required (amps) NRV Fitted ABYC Specifications 13.6-volts DC (GPH=Gallons Per Hour) ISO Specifications 12.0-volts DC (LPH=Liters Per Hour) 0 ft. Head GPH/amps 3.3 ft. Head GPH/amps 6.7 ft. Head GPH/amps 0m Head LPH/amps 1m Head LPH/amps 2m Head LPH/amps Max Head (ft@13.6V/m@12V) T500 3 N 457/1.6 219/1.5 25/1.4 1530/1.6 757/1.3 0 5.6/1.5 3 Y 432/1.6 191/1.5 33/1.5 1368/1.6 577/1.3 0 5.6/1.5 T800 5 N 825/4.0 460/3.6 287/3.4 2314/3.6 2071/3.6 1002/3.2 10.9/2.6 5 Y 839/3.9 452/3.5 276/3.4 2274/3.6 1596/3.6 882/3.2 10.9/2.6 T1200 6 N 1146/4.0 654/3.8 419/3.5 4140/3.7 2650/3.6 1633/3.2 11.2/2.7 6 Y 834/4.0 549/3.6 351/3.5 3000/3.7 2000/3.6 1122/3.0 11.2/2.7 24 Volt Specifications Model Automotive Fuse Required (amps) NRV Fitted ABYC Specifications 27.2-volts DC (GPH=Gallons Per Hour) ISO Specifications 24.0-volts DC (LPH=Liters Per Hour) 0 ft. Head GPH/amps 3.3 ft. Head GPH/amps 6.7 ft. Head GPH/amps 0m Head LPH/amps 1m Head LPH/amps 2m Head LPH/amps Max Head (ft@27.2V/m@24V) T800 2 N 835/1.9 468/1.8 299/1.7 2268/1.8 2071/1.8 982/1.6 11/3.3 2 Y 832/1.9 465/1.8 283/1.7 2228/1.8 2042/1.8 864/1.6 11/3.3 T1200 3 N 1175/2.0 680/2.0 459/1.8 3912/1.7 2650/1.7 1302/1.5 10.7/2.7 3 Y 862/2.0 593/1.9 372/1.8 2912/1.8 2053/1.7 946/1.5 10.7/2.7

RkJQdWJsaXNoZXIy MjM2MTk=